| <!--{ |
| "Title": "A Quick Guide to Go's Assembler", |
| "Path": "/doc/asm" |
| }--> |
| |
| <h2 id="introduction">A Quick Guide to Go's Assembler</h2> |
| |
| <p> |
| This document is a quick outline of the unusual form of assembly language used by the <code>gc</code> Go compiler. |
| The document is not comprehensive. |
| </p> |
| |
| <p> |
| The assembler is based on the input style of the Plan 9 assemblers, which is documented in detail |
| <a href="https://9p.io/sys/doc/asm.html">elsewhere</a>. |
| If you plan to write assembly language, you should read that document although much of it is Plan 9-specific. |
| The current document provides a summary of the syntax and the differences with |
| what is explained in that document, and |
| describes the peculiarities that apply when writing assembly code to interact with Go. |
| </p> |
| |
| <p> |
| The most important thing to know about Go's assembler is that it is not a direct representation of the underlying machine. |
| Some of the details map precisely to the machine, but some do not. |
| This is because the compiler suite (see |
| <a href="https://9p.io/sys/doc/compiler.html">this description</a>) |
| needs no assembler pass in the usual pipeline. |
| Instead, the compiler operates on a kind of semi-abstract instruction set, |
| and instruction selection occurs partly after code generation. |
| The assembler works on the semi-abstract form, so |
| when you see an instruction like <code>MOV</code> |
| what the toolchain actually generates for that operation might |
| not be a move instruction at all, perhaps a clear or load. |
| Or it might correspond exactly to the machine instruction with that name. |
| In general, machine-specific operations tend to appear as themselves, while more general concepts like |
| memory move and subroutine call and return are more abstract. |
| The details vary with architecture, and we apologize for the imprecision; the situation is not well-defined. |
| </p> |
| |
| <p> |
| The assembler program is a way to parse a description of that |
| semi-abstract instruction set and turn it into instructions to be |
| input to the linker. |
| If you want to see what the instructions look like in assembly for a given architecture, say amd64, there |
| are many examples in the sources of the standard library, in packages such as |
| <a href="/pkg/runtime/"><code>runtime</code></a> and |
| <a href="/pkg/math/big/"><code>math/big</code></a>. |
| You can also examine what the compiler emits as assembly code |
| (the actual output may differ from what you see here): |
| </p> |
| |
| <pre> |
| $ cat x.go |
| package main |
| |
| func main() { |
| println(3) |
| } |
| $ GOOS=linux GOARCH=amd64 go tool compile -S x.go # or: go build -gcflags -S x.go |
| "".main STEXT size=74 args=0x0 locals=0x10 |
| 0x0000 00000 (x.go:3) TEXT "".main(SB), $16-0 |
| 0x0000 00000 (x.go:3) MOVQ (TLS), CX |
| 0x0009 00009 (x.go:3) CMPQ SP, 16(CX) |
| 0x000d 00013 (x.go:3) JLS 67 |
| 0x000f 00015 (x.go:3) SUBQ $16, SP |
| 0x0013 00019 (x.go:3) MOVQ BP, 8(SP) |
| 0x0018 00024 (x.go:3) LEAQ 8(SP), BP |
| 0x001d 00029 (x.go:3) FUNCDATA $0, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB) |
| 0x001d 00029 (x.go:3) FUNCDATA $1, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB) |
| 0x001d 00029 (x.go:3) FUNCDATA $2, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB) |
| 0x001d 00029 (x.go:4) PCDATA $0, $0 |
| 0x001d 00029 (x.go:4) PCDATA $1, $0 |
| 0x001d 00029 (x.go:4) CALL runtime.printlock(SB) |
| 0x0022 00034 (x.go:4) MOVQ $3, (SP) |
| 0x002a 00042 (x.go:4) CALL runtime.printint(SB) |
| 0x002f 00047 (x.go:4) CALL runtime.printnl(SB) |
| 0x0034 00052 (x.go:4) CALL runtime.printunlock(SB) |
| 0x0039 00057 (x.go:5) MOVQ 8(SP), BP |
| 0x003e 00062 (x.go:5) ADDQ $16, SP |
| 0x0042 00066 (x.go:5) RET |
| 0x0043 00067 (x.go:5) NOP |
| 0x0043 00067 (x.go:3) PCDATA $1, $-1 |
| 0x0043 00067 (x.go:3) PCDATA $0, $-1 |
| 0x0043 00067 (x.go:3) CALL runtime.morestack_noctxt(SB) |
| 0x0048 00072 (x.go:3) JMP 0 |
| ... |
| </pre> |
| |
| <p> |
| The <code>FUNCDATA</code> and <code>PCDATA</code> directives contain information |
| for use by the garbage collector; they are introduced by the compiler. |
| </p> |
| |
| <p> |
| To see what gets put in the binary after linking, use <code>go tool objdump</code>: |
| </p> |
| |
| <pre> |
| $ go build -o x.exe x.go |
| $ go tool objdump -s main.main x.exe |
| TEXT main.main(SB) /tmp/x.go |
| x.go:3 0x10501c0 65488b0c2530000000 MOVQ GS:0x30, CX |
| x.go:3 0x10501c9 483b6110 CMPQ 0x10(CX), SP |
| x.go:3 0x10501cd 7634 JBE 0x1050203 |
| x.go:3 0x10501cf 4883ec10 SUBQ $0x10, SP |
| x.go:3 0x10501d3 48896c2408 MOVQ BP, 0x8(SP) |
| x.go:3 0x10501d8 488d6c2408 LEAQ 0x8(SP), BP |
| x.go:4 0x10501dd e86e45fdff CALL runtime.printlock(SB) |
| x.go:4 0x10501e2 48c7042403000000 MOVQ $0x3, 0(SP) |
| x.go:4 0x10501ea e8e14cfdff CALL runtime.printint(SB) |
| x.go:4 0x10501ef e8ec47fdff CALL runtime.printnl(SB) |
| x.go:4 0x10501f4 e8d745fdff CALL runtime.printunlock(SB) |
| x.go:5 0x10501f9 488b6c2408 MOVQ 0x8(SP), BP |
| x.go:5 0x10501fe 4883c410 ADDQ $0x10, SP |
| x.go:5 0x1050202 c3 RET |
| x.go:3 0x1050203 e83882ffff CALL runtime.morestack_noctxt(SB) |
| x.go:3 0x1050208 ebb6 JMP main.main(SB) |
| </pre> |
| |
| <h3 id="constants">Constants</h3> |
| |
| <p> |
| Although the assembler takes its guidance from the Plan 9 assemblers, |
| it is a distinct program, so there are some differences. |
| One is in constant evaluation. |
| Constant expressions in the assembler are parsed using Go's operator |
| precedence, not the C-like precedence of the original. |
| Thus <code>3&1<<2</code> is 4, not 0—it parses as <code>(3&1)<<2</code> |
| not <code>3&(1<<2)</code>. |
| Also, constants are always evaluated as 64-bit unsigned integers. |
| Thus <code>-2</code> is not the integer value minus two, |
| but the unsigned 64-bit integer with the same bit pattern. |
| The distinction rarely matters but |
| to avoid ambiguity, division or right shift where the right operand's |
| high bit is set is rejected. |
| </p> |
| |
| <h3 id="symbols">Symbols</h3> |
| |
| <p> |
| Some symbols, such as <code>R1</code> or <code>LR</code>, |
| are predefined and refer to registers. |
| The exact set depends on the architecture. |
| </p> |
| |
| <p> |
| There are four predeclared symbols that refer to pseudo-registers. |
| These are not real registers, but rather virtual registers maintained by |
| the toolchain, such as a frame pointer. |
| The set of pseudo-registers is the same for all architectures: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>FP</code>: Frame pointer: arguments and locals. |
| </li> |
| |
| <li> |
| <code>PC</code>: Program counter: |
| jumps and branches. |
| </li> |
| |
| <li> |
| <code>SB</code>: Static base pointer: global symbols. |
| </li> |
| |
| <li> |
| <code>SP</code>: Stack pointer: the highest address within the local stack frame. |
| </li> |
| |
| </ul> |
| |
| <p> |
| All user-defined symbols are written as offsets to the pseudo-registers |
| <code>FP</code> (arguments and locals) and <code>SB</code> (globals). |
| </p> |
| |
| <p> |
| The <code>SB</code> pseudo-register can be thought of as the origin of memory, so the symbol <code>foo(SB)</code> |
| is the name <code>foo</code> as an address in memory. |
| This form is used to name global functions and data. |
| Adding <code><></code> to the name, as in <span style="white-space: nowrap"><code>foo<>(SB)</code></span>, makes the name |
| visible only in the current source file, like a top-level <code>static</code> declaration in a C file. |
| Adding an offset to the name refers to that offset from the symbol's address, so |
| <code>foo+4(SB)</code> is four bytes past the start of <code>foo</code>. |
| </p> |
| |
| <p> |
| The <code>FP</code> pseudo-register is a virtual frame pointer |
| used to refer to function arguments. |
| The compilers maintain a virtual frame pointer and refer to the arguments on the stack as offsets from that pseudo-register. |
| Thus <code>0(FP)</code> is the first argument to the function, |
| <code>8(FP)</code> is the second (on a 64-bit machine), and so on. |
| However, when referring to a function argument this way, it is necessary to place a name |
| at the beginning, as in <code>first_arg+0(FP)</code> and <code>second_arg+8(FP)</code>. |
| (The meaning of the offset—offset from the frame pointer—distinct |
| from its use with <code>SB</code>, where it is an offset from the symbol.) |
| The assembler enforces this convention, rejecting plain <code>0(FP)</code> and <code>8(FP)</code>. |
| The actual name is semantically irrelevant but should be used to document |
| the argument's name. |
| It is worth stressing that <code>FP</code> is always a |
| pseudo-register, not a hardware |
| register, even on architectures with a hardware frame pointer. |
| </p> |
| |
| <p> |
| For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the argument names |
| and offsets match. |
| On 32-bit systems, the low and high 32 bits of a 64-bit value are distinguished by adding |
| a <code>_lo</code> or <code>_hi</code> suffix to the name, as in <code>arg_lo+0(FP)</code> or <code>arg_hi+4(FP)</code>. |
| If a Go prototype does not name its result, the expected assembly name is <code>ret</code>. |
| </p> |
| |
| <p> |
| The <code>SP</code> pseudo-register is a virtual stack pointer |
| used to refer to frame-local variables and the arguments being |
| prepared for function calls. |
| It points to the highest address within the local stack frame, so references should use negative offsets |
| in the range [−framesize, 0): |
| <code>x-8(SP)</code>, <code>y-4(SP)</code>, and so on. |
| </p> |
| |
| <p> |
| On architectures with a hardware register named <code>SP</code>, |
| the name prefix distinguishes |
| references to the virtual stack pointer from references to the architectural |
| <code>SP</code> register. |
| That is, <code>x-8(SP)</code> and <code>-8(SP)</code> |
| are different memory locations: |
| the first refers to the virtual stack pointer pseudo-register, |
| while the second refers to the |
| hardware's <code>SP</code> register. |
| </p> |
| |
| <p> |
| On machines where <code>SP</code> and <code>PC</code> are |
| traditionally aliases for a physical, numbered register, |
| in the Go assembler the names <code>SP</code> and <code>PC</code> |
| are still treated specially; |
| for instance, references to <code>SP</code> require a symbol, |
| much like <code>FP</code>. |
| To access the actual hardware register use the true <code>R</code> name. |
| For example, on the ARM architecture the hardware |
| <code>SP</code> and <code>PC</code> are accessible as |
| <code>R13</code> and <code>R15</code>. |
| </p> |
| |
| <p> |
| Branches and direct jumps are always written as offsets to the PC, or as |
| jumps to labels: |
| </p> |
| |
| <pre> |
| label: |
| MOVW $0, R1 |
| JMP label |
| </pre> |
| |
| <p> |
| Each label is visible only within the function in which it is defined. |
| It is therefore permitted for multiple functions in a file to define |
| and use the same label names. |
| Direct jumps and call instructions can target text symbols, |
| such as <code>name(SB)</code>, but not offsets from symbols, |
| such as <code>name+4(SB)</code>. |
| </p> |
| |
| <p> |
| Instructions, registers, and assembler directives are always in UPPER CASE to remind you |
| that assembly programming is a fraught endeavor. |
| (Exception: the <code>g</code> register renaming on ARM.) |
| </p> |
| |
| <p> |
| In Go object files and binaries, the full name of a symbol is the |
| package path followed by a period and the symbol name: |
| <code>fmt.Printf</code> or <code>math/rand.Int</code>. |
| Because the assembler's parser treats period and slash as punctuation, |
| those strings cannot be used directly as identifier names. |
| Instead, the assembler allows the middle dot character U+00B7 |
| and the division slash U+2215 in identifiers and rewrites them to |
| plain period and slash. |
| Within an assembler source file, the symbols above are written as |
| <code>fmt·Printf</code> and <code>math∕rand·Int</code>. |
| The assembly listings generated by the compilers when using the <code>-S</code> flag |
| show the period and slash directly instead of the Unicode replacements |
| required by the assemblers. |
| </p> |
| |
| <p> |
| Most hand-written assembly files do not include the full package path |
| in symbol names, because the linker inserts the package path of the current |
| object file at the beginning of any name starting with a period: |
| in an assembly source file within the math/rand package implementation, |
| the package's Int function can be referred to as <code>·Int</code>. |
| This convention avoids the need to hard-code a package's import path in its |
| own source code, making it easier to move the code from one location to another. |
| </p> |
| |
| <h3 id="directives">Directives</h3> |
| |
| <p> |
| The assembler uses various directives to bind text and data to symbol names. |
| For example, here is a simple complete function definition. The <code>TEXT</code> |
| directive declares the symbol <code>runtime·profileloop</code> and the instructions |
| that follow form the body of the function. |
| The last instruction in a <code>TEXT</code> block must be some sort of jump, usually a <code>RET</code> (pseudo-)instruction. |
| (If it's not, the linker will append a jump-to-itself instruction; there is no fallthrough in <code>TEXTs</code>.) |
| After the symbol, the arguments are flags (see below) |
| and the frame size, a constant (but see below): |
| </p> |
| |
| <pre> |
| TEXT runtime·profileloop(SB),NOSPLIT,$8 |
| MOVQ $runtime·profileloop1(SB), CX |
| MOVQ CX, 0(SP) |
| CALL runtime·externalthreadhandler(SB) |
| RET |
| </pre> |
| |
| <p> |
| In the general case, the frame size is followed by an argument size, separated by a minus sign. |
| (It's not a subtraction, just idiosyncratic syntax.) |
| The frame size <code>$24-8</code> states that the function has a 24-byte frame |
| and is called with 8 bytes of argument, which live on the caller's frame. |
| If <code>NOSPLIT</code> is not specified for the <code>TEXT</code>, |
| the argument size must be provided. |
| For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the |
| argument size is correct. |
| </p> |
| |
| <p> |
| Note that the symbol name uses a middle dot to separate the components and is specified as an offset from the |
| static base pseudo-register <code>SB</code>. |
| This function would be called from Go source for package <code>runtime</code> using the |
| simple name <code>profileloop</code>. |
| </p> |
| |
| <p> |
| Global data symbols are defined by a sequence of initializing |
| <code>DATA</code> directives followed by a <code>GLOBL</code> directive. |
| Each <code>DATA</code> directive initializes a section of the |
| corresponding memory. |
| The memory not explicitly initialized is zeroed. |
| The general form of the <code>DATA</code> directive is |
| |
| <pre> |
| DATA symbol+offset(SB)/width, value |
| </pre> |
| |
| <p> |
| which initializes the symbol memory at the given offset and width with the given value. |
| The <code>DATA</code> directives for a given symbol must be written with increasing offsets. |
| </p> |
| |
| <p> |
| The <code>GLOBL</code> directive declares a symbol to be global. |
| The arguments are optional flags and the size of the data being declared as a global, |
| which will have initial value all zeros unless a <code>DATA</code> directive |
| has initialized it. |
| The <code>GLOBL</code> directive must follow any corresponding <code>DATA</code> directives. |
| </p> |
| |
| <p> |
| For example, |
| </p> |
| |
| <pre> |
| DATA divtab<>+0x00(SB)/4, $0xf4f8fcff |
| DATA divtab<>+0x04(SB)/4, $0xe6eaedf0 |
| ... |
| DATA divtab<>+0x3c(SB)/4, $0x81828384 |
| GLOBL divtab<>(SB), RODATA, $64 |
| |
| GLOBL runtime·tlsoffset(SB), NOPTR, $4 |
| </pre> |
| |
| <p> |
| declares and initializes <code>divtab<></code>, a read-only 64-byte table of 4-byte integer values, |
| and declares <code>runtime·tlsoffset</code>, a 4-byte, implicitly zeroed variable that |
| contains no pointers. |
| </p> |
| |
| <p> |
| There may be one or two arguments to the directives. |
| If there are two, the first is a bit mask of flags, |
| which can be written as numeric expressions, added or or-ed together, |
| or can be set symbolically for easier absorption by a human. |
| Their values, defined in the standard <code>#include</code> file <code>textflag.h</code>, are: |
| </p> |
| |
| <ul> |
| <li> |
| <code>NOPROF</code> = 1 |
| <br> |
| (For <code>TEXT</code> items.) |
| Don't profile the marked function. This flag is deprecated. |
| </li> |
| <li> |
| <code>DUPOK</code> = 2 |
| <br> |
| It is legal to have multiple instances of this symbol in a single binary. |
| The linker will choose one of the duplicates to use. |
| </li> |
| <li> |
| <code>NOSPLIT</code> = 4 |
| <br> |
| (For <code>TEXT</code> items.) |
| Don't insert the preamble to check if the stack must be split. |
| The frame for the routine, plus anything it calls, must fit in the |
| spare space remaining in the current stack segment. |
| Used to protect routines such as the stack splitting code itself. |
| </li> |
| <li> |
| <code>RODATA</code> = 8 |
| <br> |
| (For <code>DATA</code> and <code>GLOBL</code> items.) |
| Put this data in a read-only section. |
| </li> |
| <li> |
| <code>NOPTR</code> = 16 |
| <br> |
| (For <code>DATA</code> and <code>GLOBL</code> items.) |
| This data contains no pointers and therefore does not need to be |
| scanned by the garbage collector. |
| </li> |
| <li> |
| <code>WRAPPER</code> = 32 |
| <br> |
| (For <code>TEXT</code> items.) |
| This is a wrapper function and should not count as disabling <code>recover</code>. |
| </li> |
| <li> |
| <code>NEEDCTXT</code> = 64 |
| <br> |
| (For <code>TEXT</code> items.) |
| This function is a closure so it uses its incoming context register. |
| </li> |
| <li> |
| <code>LOCAL</code> = 128 |
| <br> |
| This symbol is local to the dynamic shared object. |
| </li> |
| <li> |
| <code>TLSBSS</code> = 256 |
| <br> |
| (For <code>DATA</code> and <code>GLOBL</code> items.) |
| Put this data in thread local storage. |
| </li> |
| <li> |
| <code>NOFRAME</code> = 512 |
| <br> |
| (For <code>TEXT</code> items.) |
| Do not insert instructions to allocate a stack frame and save/restore the return |
| address, even if this is not a leaf function. |
| Only valid on functions that declare a frame size of 0. |
| </li> |
| <li> |
| <code>TOPFRAME</code> = 2048 |
| <br> |
| (For <code>TEXT</code> items.) |
| Function is the outermost frame of the call stack. Traceback should stop at this function. |
| </li> |
| </ul> |
| |
| <h3 id="data-offsets">Interacting with Go types and constants</h3> |
| |
| <p> |
| If a package has any .s files, then <code>go build</code> will direct |
| the compiler to emit a special header called <code>go_asm.h</code>, |
| which the .s files can then <code>#include</code>. |
| The file contains symbolic <code>#define</code> constants for the |
| offsets of Go struct fields, the sizes of Go struct types, and most |
| Go <code>const</code> declarations defined in the current package. |
| Go assembly should avoid making assumptions about the layout of Go |
| types and instead use these constants. |
| This improves the readability of assembly code, and keeps it robust to |
| changes in data layout either in the Go type definitions or in the |
| layout rules used by the Go compiler. |
| </p> |
| |
| <p> |
| Constants are of the form <code>const_<i>name</i></code>. |
| For example, given the Go declaration <code>const bufSize = |
| 1024</code>, assembly code can refer to the value of this constant |
| as <code>const_bufSize</code>. |
| </p> |
| |
| <p> |
| Field offsets are of the form <code><i>type</i>_<i>field</i></code>. |
| Struct sizes are of the form <code><i>type</i>__size</code>. |
| For example, consider the following Go definition: |
| </p> |
| |
| <pre> |
| type reader struct { |
| buf [bufSize]byte |
| r int |
| } |
| </pre> |
| |
| <p> |
| Assembly can refer to the size of this struct |
| as <code>reader__size</code> and the offsets of the two fields |
| as <code>reader_buf</code> and <code>reader_r</code>. |
| Hence, if register <code>R1</code> contains a pointer to |
| a <code>reader</code>, assembly can reference the <code>r</code> field |
| as <code>reader_r(R1)</code>. |
| </p> |
| |
| <p> |
| If any of these <code>#define</code> names are ambiguous (for example, |
| a struct with a <code>_size</code> field), <code>#include |
| "go_asm.h"</code> will fail with a "redefinition of macro" error. |
| </p> |
| |
| <h3 id="runtime">Runtime Coordination</h3> |
| |
| <p> |
| For garbage collection to run correctly, the runtime must know the |
| location of pointers in all global data and in most stack frames. |
| The Go compiler emits this information when compiling Go source files, |
| but assembly programs must define it explicitly. |
| </p> |
| |
| <p> |
| A data symbol marked with the <code>NOPTR</code> flag (see above) |
| is treated as containing no pointers to runtime-allocated data. |
| A data symbol with the <code>RODATA</code> flag |
| is allocated in read-only memory and is therefore treated |
| as implicitly marked <code>NOPTR</code>. |
| A data symbol with a total size smaller than a pointer |
| is also treated as implicitly marked <code>NOPTR</code>. |
| It is not possible to define a symbol containing pointers in an assembly source file; |
| such a symbol must be defined in a Go source file instead. |
| Assembly source can still refer to the symbol by name |
| even without <code>DATA</code> and <code>GLOBL</code> directives. |
| A good general rule of thumb is to define all non-<code>RODATA</code> |
| symbols in Go instead of in assembly. |
| </p> |
| |
| <p> |
| Each function also needs annotations giving the location of |
| live pointers in its arguments, results, and local stack frame. |
| For an assembly function with no pointer results and |
| either no local stack frame or no function calls, |
| the only requirement is to define a Go prototype for the function |
| in a Go source file in the same package. The name of the assembly |
| function must not contain the package name component (for example, |
| function <code>Syscall</code> in package <code>syscall</code> should |
| use the name <code>·Syscall</code> instead of the equivalent name |
| <code>syscall·Syscall</code> in its <code>TEXT</code> directive). |
| For more complex situations, explicit annotation is needed. |
| These annotations use pseudo-instructions defined in the standard |
| <code>#include</code> file <code>funcdata.h</code>. |
| </p> |
| |
| <p> |
| If a function has no arguments and no results, |
| the pointer information can be omitted. |
| This is indicated by an argument size annotation of <code>$<i>n</i>-0</code> |
| on the <code>TEXT</code> instruction. |
| Otherwise, pointer information must be provided by |
| a Go prototype for the function in a Go source file, |
| even for assembly functions not called directly from Go. |
| (The prototype will also let <code>go</code> <code>vet</code> check the argument references.) |
| At the start of the function, the arguments are assumed |
| to be initialized but the results are assumed uninitialized. |
| If the results will hold live pointers during a call instruction, |
| the function should start by zeroing the results and then |
| executing the pseudo-instruction <code>GO_RESULTS_INITIALIZED</code>. |
| This instruction records that the results are now initialized |
| and should be scanned during stack movement and garbage collection. |
| It is typically easier to arrange that assembly functions do not |
| return pointers or do not contain call instructions; |
| no assembly functions in the standard library use |
| <code>GO_RESULTS_INITIALIZED</code>. |
| </p> |
| |
| <p> |
| If a function has no local stack frame, |
| the pointer information can be omitted. |
| This is indicated by a local frame size annotation of <code>$0-<i>n</i></code> |
| on the <code>TEXT</code> instruction. |
| The pointer information can also be omitted if the |
| function contains no call instructions. |
| Otherwise, the local stack frame must not contain pointers, |
| and the assembly must confirm this fact by executing the |
| pseudo-instruction <code>NO_LOCAL_POINTERS</code>. |
| Because stack resizing is implemented by moving the stack, |
| the stack pointer may change during any function call: |
| even pointers to stack data must not be kept in local variables. |
| </p> |
| |
| <p> |
| Assembly functions should always be given Go prototypes, |
| both to provide pointer information for the arguments and results |
| and to let <code>go</code> <code>vet</code> check that |
| the offsets being used to access them are correct. |
| </p> |
| |
| <h2 id="architectures">Architecture-specific details</h2> |
| |
| <p> |
| It is impractical to list all the instructions and other details for each machine. |
| To see what instructions are defined for a given machine, say ARM, |
| look in the source for the <code>obj</code> support library for |
| that architecture, located in the directory <code>src/cmd/internal/obj/arm</code>. |
| In that directory is a file <code>a.out.go</code>; it contains |
| a long list of constants starting with <code>A</code>, like this: |
| </p> |
| |
| <pre> |
| const ( |
| AAND = obj.ABaseARM + obj.A_ARCHSPECIFIC + iota |
| AEOR |
| ASUB |
| ARSB |
| AADD |
| ... |
| </pre> |
| |
| <p> |
| This is the list of instructions and their spellings as known to the assembler and linker for that architecture. |
| Each instruction begins with an initial capital <code>A</code> in this list, so <code>AAND</code> |
| represents the bitwise and instruction, |
| <code>AND</code> (without the leading <code>A</code>), |
| and is written in assembly source as <code>AND</code>. |
| The enumeration is mostly in alphabetical order. |
| (The architecture-independent <code>AXXX</code>, defined in the |
| <code>cmd/internal/obj</code> package, |
| represents an invalid instruction). |
| The sequence of the <code>A</code> names has nothing to do with the actual |
| encoding of the machine instructions. |
| The <code>cmd/internal/obj</code> package takes care of that detail. |
| </p> |
| |
| <p> |
| The instructions for both the 386 and AMD64 architectures are listed in |
| <code>cmd/internal/obj/x86/a.out.go</code>. |
| </p> |
| |
| <p> |
| The architectures share syntax for common addressing modes such as |
| <code>(R1)</code> (register indirect), |
| <code>4(R1)</code> (register indirect with offset), and |
| <code>$foo(SB)</code> (absolute address). |
| The assembler also supports some (not necessarily all) addressing modes |
| specific to each architecture. |
| The sections below list these. |
| </p> |
| |
| <p> |
| One detail evident in the examples from the previous sections is that data in the instructions flows from left to right: |
| <code>MOVQ</code> <code>$0,</code> <code>CX</code> clears <code>CX</code>. |
| This rule applies even on architectures where the conventional notation uses the opposite direction. |
| </p> |
| |
| <p> |
| Here follow some descriptions of key Go-specific details for the supported architectures. |
| </p> |
| |
| <h3 id="x86">32-bit Intel 386</h3> |
| |
| <p> |
| The runtime pointer to the <code>g</code> structure is maintained |
| through the value of an otherwise unused (as far as Go is concerned) register in the MMU. |
| In the runtime package, assembly code can include <code>go_tls.h</code>, which defines |
| an OS- and architecture-dependent macro <code>get_tls</code> for accessing this register. |
| The <code>get_tls</code> macro takes one argument, which is the register to load the |
| <code>g</code> pointer into. |
| </p> |
| |
| <p> |
| For example, the sequence to load <code>g</code> and <code>m</code> |
| using <code>CX</code> looks like this: |
| </p> |
| |
| <pre> |
| #include "go_tls.h" |
| #include "go_asm.h" |
| ... |
| get_tls(CX) |
| MOVL g(CX), AX // Move g into AX. |
| MOVL g_m(AX), BX // Move g.m into BX. |
| </pre> |
| |
| <p> |
| The <code>get_tls</code> macro is also defined on <a href="#amd64">amd64</a>. |
| </p> |
| |
| <p> |
| Addressing modes: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code>. |
| </li> |
| |
| <li> |
| <code>64(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code> plus 64. |
| These modes accept only 1, 2, 4, and 8 as scale factors. |
| </li> |
| |
| </ul> |
| |
| <p> |
| When using the compiler and assembler's |
| <code>-dynlink</code> or <code>-shared</code> modes, |
| any load or store of a fixed memory location such as a global variable |
| must be assumed to overwrite <code>CX</code>. |
| Therefore, to be safe for use with these modes, |
| assembly sources should typically avoid CX except between memory references. |
| </p> |
| |
| <h3 id="amd64">64-bit Intel 386 (a.k.a. amd64)</h3> |
| |
| <p> |
| The two architectures behave largely the same at the assembler level. |
| Assembly code to access the <code>m</code> and <code>g</code> |
| pointers on the 64-bit version is the same as on the 32-bit 386, |
| except it uses <code>MOVQ</code> rather than <code>MOVL</code>: |
| </p> |
| |
| <pre> |
| get_tls(CX) |
| MOVQ g(CX), AX // Move g into AX. |
| MOVQ g_m(AX), BX // Move g.m into BX. |
| </pre> |
| |
| <p> |
| Register <code>BP</code> is callee-save. |
| The assembler automatically inserts <code>BP</code> save/restore when frame size is larger than zero. |
| Using <code>BP</code> as a general purpose register is allowed, |
| however it can interfere with sampling-based profiling. |
| </p> |
| |
| <h3 id="arm">ARM</h3> |
| |
| <p> |
| The registers <code>R10</code> and <code>R11</code> |
| are reserved by the compiler and linker. |
| </p> |
| |
| <p> |
| <code>R10</code> points to the <code>g</code> (goroutine) structure. |
| Within assembler source code, this pointer must be referred to as <code>g</code>; |
| the name <code>R10</code> is not recognized. |
| </p> |
| |
| <p> |
| To make it easier for people and compilers to write assembly, the ARM linker |
| allows general addressing forms and pseudo-operations like <code>DIV</code> or <code>MOD</code> |
| that may not be expressible using a single hardware instruction. |
| It implements these forms as multiple instructions, often using the <code>R11</code> register |
| to hold temporary values. |
| Hand-written assembly can use <code>R11</code>, but doing so requires |
| being sure that the linker is not also using it to implement any of the other |
| instructions in the function. |
| </p> |
| |
| <p> |
| When defining a <code>TEXT</code>, specifying frame size <code>$-4</code> |
| tells the linker that this is a leaf function that does not need to save <code>LR</code> on entry. |
| </p> |
| |
| <p> |
| The name <code>SP</code> always refers to the virtual stack pointer described earlier. |
| For the hardware register, use <code>R13</code>. |
| </p> |
| |
| <p> |
| Condition code syntax is to append a period and the one- or two-letter code to the instruction, |
| as in <code>MOVW.EQ</code>. |
| Multiple codes may be appended: <code>MOVM.IA.W</code>. |
| The order of the code modifiers is irrelevant. |
| </p> |
| |
| <p> |
| Addressing modes: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>R0->16</code> |
| <br> |
| <code>R0>>16</code> |
| <br> |
| <code>R0<<16</code> |
| <br> |
| <code>R0@>16</code>: |
| For <code><<</code>, left shift <code>R0</code> by 16 bits. |
| The other codes are <code>-></code> (arithmetic right shift), |
| <code>>></code> (logical right shift), and |
| <code>@></code> (rotate right). |
| </li> |
| |
| <li> |
| <code>R0->R1</code> |
| <br> |
| <code>R0>>R1</code> |
| <br> |
| <code>R0<<R1</code> |
| <br> |
| <code>R0@>R1</code>: |
| For <code><<</code>, left shift <code>R0</code> by the count in <code>R1</code>. |
| The other codes are <code>-></code> (arithmetic right shift), |
| <code>>></code> (logical right shift), and |
| <code>@></code> (rotate right). |
| |
| </li> |
| |
| <li> |
| <code>[R0,g,R12-R15]</code>: For multi-register instructions, the set comprising |
| <code>R0</code>, <code>g</code>, and <code>R12</code> through <code>R15</code> inclusive. |
| </li> |
| |
| <li> |
| <code>(R5, R6)</code>: Destination register pair. |
| </li> |
| |
| </ul> |
| |
| <h3 id="arm64">ARM64</h3> |
| |
| <p> |
| <code>R18</code> is the "platform register", reserved on the Apple platform. |
| To prevent accidental misuse, the register is named <code>R18_PLATFORM</code>. |
| <code>R27</code> and <code>R28</code> are reserved by the compiler and linker. |
| <code>R29</code> is the frame pointer. |
| <code>R30</code> is the link register. |
| </p> |
| |
| <p> |
| Instruction modifiers are appended to the instruction following a period. |
| The only modifiers are <code>P</code> (postincrement) and <code>W</code> |
| (preincrement): |
| <code>MOVW.P</code>, <code>MOVW.W</code> |
| </p> |
| |
| <p> |
| Addressing modes: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>R0->16</code> |
| <br> |
| <code>R0>>16</code> |
| <br> |
| <code>R0<<16</code> |
| <br> |
| <code>R0@>16</code>: |
| These are the same as on the 32-bit ARM. |
| </li> |
| |
| <li> |
| <code>$(8<<12)</code>: |
| Left shift the immediate value <code>8</code> by <code>12</code> bits. |
| </li> |
| |
| <li> |
| <code>8(R0)</code>: |
| Add the value of <code>R0</code> and <code>8</code>. |
| </li> |
| |
| <li> |
| <code>(R2)(R0)</code>: |
| The location at <code>R0</code> plus <code>R2</code>. |
| </li> |
| |
| <li> |
| <code>R0.UXTB</code> |
| <br> |
| <code>R0.UXTB<<imm</code>: |
| <code>UXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and zero-extend it to the size of <code>R0</code>. |
| <code>R0.UXTB<<imm</code>: left shift the result of <code>R0.UXTB</code> by <code>imm</code> bits. |
| The <code>imm</code> value can be 0, 1, 2, 3, or 4. |
| The other extensions include <code>UXTH</code> (16-bit), <code>UXTW</code> (32-bit), and <code>UXTX</code> (64-bit). |
| </li> |
| |
| <li> |
| <code>R0.SXTB</code> |
| <br> |
| <code>R0.SXTB<<imm</code>: |
| <code>SXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and sign-extend it to the size of <code>R0</code>. |
| <code>R0.SXTB<<imm</code>: left shift the result of <code>R0.SXTB</code> by <code>imm</code> bits. |
| The <code>imm</code> value can be 0, 1, 2, 3, or 4. |
| The other extensions include <code>SXTH</code> (16-bit), <code>SXTW</code> (32-bit), and <code>SXTX</code> (64-bit). |
| </li> |
| |
| <li> |
| <code>(R5, R6)</code>: Register pair for <code>LDAXP</code>/<code>LDP</code>/<code>LDXP</code>/<code>STLXP</code>/<code>STP</code>/<code>STP</code>. |
| </li> |
| |
| </ul> |
| |
| <p> |
| Reference: <a href="/pkg/cmd/internal/obj/arm64">Go ARM64 Assembly Instructions Reference Manual</a> |
| </p> |
| |
| <h3 id="ppc64">PPC64</h3> |
| |
| <p> |
| This assembler is used by GOARCH values ppc64 and ppc64le. |
| </p> |
| |
| <p> |
| Reference: <a href="/pkg/cmd/internal/obj/ppc64">Go PPC64 Assembly Instructions Reference Manual</a> |
| </p> |
| |
| </ul> |
| |
| <h3 id="s390x">IBM z/Architecture, a.k.a. s390x</h3> |
| |
| <p> |
| The registers <code>R10</code> and <code>R11</code> are reserved. |
| The assembler uses them to hold temporary values when assembling some instructions. |
| </p> |
| |
| <p> |
| <code>R13</code> points to the <code>g</code> (goroutine) structure. |
| This register must be referred to as <code>g</code>; the name <code>R13</code> is not recognized. |
| </p> |
| |
| <p> |
| <code>R15</code> points to the stack frame and should typically only be accessed using the |
| virtual registers <code>SP</code> and <code>FP</code>. |
| </p> |
| |
| <p> |
| Load- and store-multiple instructions operate on a range of registers. |
| The range of registers is specified by a start register and an end register. |
| For example, <code>LMG</code> <code>(R9),</code> <code>R5,</code> <code>R7</code> would load |
| <code>R5</code>, <code>R6</code> and <code>R7</code> with the 64-bit values at |
| <code>0(R9)</code>, <code>8(R9)</code> and <code>16(R9)</code> respectively. |
| </p> |
| |
| <p> |
| Storage-and-storage instructions such as <code>MVC</code> and <code>XC</code> are written |
| with the length as the first argument. |
| For example, <code>XC</code> <code>$8,</code> <code>(R9),</code> <code>(R9)</code> would clear |
| eight bytes at the address specified in <code>R9</code>. |
| </p> |
| |
| <p> |
| If a vector instruction takes a length or an index as an argument then it will be the |
| first argument. |
| For example, <code>VLEIF</code> <code>$1,</code> <code>$16,</code> <code>V2</code> will load |
| the value sixteen into index one of <code>V2</code>. |
| Care should be taken when using vector instructions to ensure that they are available at |
| runtime. |
| To use vector instructions a machine must have both the vector facility (bit 129 in the |
| facility list) and kernel support. |
| Without kernel support a vector instruction will have no effect (it will be equivalent |
| to a <code>NOP</code> instruction). |
| </p> |
| |
| <p> |
| Addressing modes: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>(R5)(R6*1)</code>: The location at <code>R5</code> plus <code>R6</code>. |
| It is a scaled mode as on the x86, but the only scale allowed is <code>1</code>. |
| </li> |
| |
| </ul> |
| |
| <h3 id="mips">MIPS, MIPS64</h3> |
| |
| <p> |
| General purpose registers are named <code>R0</code> through <code>R31</code>, |
| floating point registers are <code>F0</code> through <code>F31</code>. |
| </p> |
| |
| <p> |
| <code>R30</code> is reserved to point to <code>g</code>. |
| <code>R23</code> is used as a temporary register. |
| </p> |
| |
| <p> |
| In a <code>TEXT</code> directive, the frame size <code>$-4</code> for MIPS or |
| <code>$-8</code> for MIPS64 instructs the linker not to save <code>LR</code>. |
| </p> |
| |
| <p> |
| <code>SP</code> refers to the virtual stack pointer. |
| For the hardware register, use <code>R29</code>. |
| </p> |
| |
| <p> |
| Addressing modes: |
| </p> |
| |
| <ul> |
| |
| <li> |
| <code>16(R1)</code>: The location at <code>R1</code> plus 16. |
| </li> |
| |
| <li> |
| <code>(R1)</code>: Alias for <code>0(R1)</code>. |
| </li> |
| |
| </ul> |
| |
| <p> |
| The value of <code>GOMIPS</code> environment variable (<code>hardfloat</code> or |
| <code>softfloat</code>) is made available to assembly code by predefining either |
| <code>GOMIPS_hardfloat</code> or <code>GOMIPS_softfloat</code>. |
| </p> |
| |
| <p> |
| The value of <code>GOMIPS64</code> environment variable (<code>hardfloat</code> or |
| <code>softfloat</code>) is made available to assembly code by predefining either |
| <code>GOMIPS64_hardfloat</code> or <code>GOMIPS64_softfloat</code>. |
| </p> |
| |
| <h3 id="unsupported_opcodes">Unsupported opcodes</h3> |
| |
| <p> |
| The assemblers are designed to support the compiler so not all hardware instructions |
| are defined for all architectures: if the compiler doesn't generate it, it might not be there. |
| If you need to use a missing instruction, there are two ways to proceed. |
| One is to update the assembler to support that instruction, which is straightforward |
| but only worthwhile if it's likely the instruction will be used again. |
| Instead, for simple one-off cases, it's possible to use the <code>BYTE</code> |
| and <code>WORD</code> directives |
| to lay down explicit data into the instruction stream within a <code>TEXT</code>. |
| Here's how the 386 runtime defines the 64-bit atomic load function. |
| </p> |
| |
| <pre> |
| // uint64 atomicload64(uint64 volatile* addr); |
| // so actually |
| // void atomicload64(uint64 *res, uint64 volatile *addr); |
| TEXT runtime·atomicload64(SB), NOSPLIT, $0-12 |
| MOVL ptr+0(FP), AX |
| TESTL $7, AX |
| JZ 2(PC) |
| MOVL 0, AX // crash with nil ptr deref |
| LEAL ret_lo+4(FP), BX |
| // MOVQ (%EAX), %MM0 |
| BYTE $0x0f; BYTE $0x6f; BYTE $0x00 |
| // MOVQ %MM0, 0(%EBX) |
| BYTE $0x0f; BYTE $0x7f; BYTE $0x03 |
| // EMMS |
| BYTE $0x0F; BYTE $0x77 |
| RET |
| </pre> |