commit | 66926cabdbdbf3431b4f172f7756e195c1c6c513 | [log] [tgz] |
---|---|---|
author | Matthieu Sarter <matthieu.sarter.external@atos.net> | Thu Apr 20 17:15:38 2017 +0200 |
committer | Ian Lance Taylor <iant@golang.org> | Thu Apr 20 23:55:11 2017 +0000 |
tree | f76f3bac955f1fad1ed6742e34c419114dcc09d6 | |
parent | 4269db69f9184e5a45c54aaee7352425a1f88bff [diff] |
libgo: fix bad value for O_CLOEXEC on AIX 7.1 On AIX 7.1, O_CLOEXEC is defined as 0x0000001000000000, which creates an integer constant overflow error when building libgo. This affects only 7.1, O_CLOEXEC is not defined on 6.1 (and defaults to O in sysinfo.go) and is defined as 0x00800000 on AIX 7.2. Issue golang/go#19200 Change-Id: If882b0cbc72426e623e8b735100d232d1b1e7c69 Reviewed-on: https://go-review.googlesource.com/41214 Reviewed-by: Ian Lance Taylor <iant@golang.org>